Choose an 8-channel ADAT mic preamp that matches the interface’s available ADAT inputs at your session rate. At 44.1 or 48 kHz, one active ADAT input can receive up to eight channels. At 88.2 or 96 kHz, you need two active ADAT inputs to receive all eight. ADAT channel limits
Check your interface first
- Look up your exact interface model and generation. Find its optical input channel map for your session rate and check which inputs are assigned to ADAT. ADAT channel limits · Focusrite’s digital I/O maps
- If the interface offers optical S/PDIF, check what that mode does to each input. On the Scarlett 16i16 4th Gen, for example, ADAT is unavailable in Optical S/PDIF mode. Focusrite’s digital I/O maps
- Count the ADAT channels you can receive at that rate. A single link carries up to eight channels at 44.1/48 kHz, four at 88.2/96 kHz and two at 176.4/192 kHz where supported. Some interfaces disable ADAT entirely at 176.4/192 kHz. ADAT channel limits
Compare the four preamps
| Preamp | Mic, line and instrument inputs | 48 V phantom power | ADAT outputs for all eight channels |
|---|---|---|---|
| Focusrite Scarlett OctoPre Dynamic | Eight combo mic/line inputs. Instrument mode on inputs 1 and 2. Inputs | XLR contacts only, switched in banks of 1–4 and 5–8. Phantom power | At 44.1/48 kHz, use the right-hand output as viewed from behind. At 88.2/96 kHz, use both. Output map |
| Audient ASP800 | Eight combo mic/line inputs. Instrument inputs on channels 1 and 2. Hardware | A switch for each channel. Input controls | At 44.1/48 kHz, use either output. Both carry the same eight channels. At 88.2/96 kHz, use both for four channels each. Output map |
| Audient ASP880 | Eight combo mic/line inputs. Instrument inputs on channels 1 and 2. Hardware | A control for each channel. Hardware | At 44.1/48 kHz, use the top output. At 88.2/96 kHz, use both for four channels each. Output map |
| Audient EVO SP8 | Eight combo mic/line inputs. Instrument mode on inputs 1 and 2. Hardware | Per channel. Select the channel, then press 48V. Input controls | At 44.1/48 kHz, use either output. Both carry the same eight channels. At 88.2/96 kHz, use both for four channels each. Output map |
At 176.4/192 kHz, the OctoPre Dynamic sends only channels 1–4 over ADAT. Viewed from the rear, the right-hand output carries channels 1 and 2 and the left carries channels 3 and 4. OctoPre output map
The ASP800, ASP880 and EVO SP8 support ADAT rates up to 96 kHz. ASP800 rates · ASP880 rates · EVO SP8 rates
Set phantom power for a mixed mic setup
Check each microphone maker’s requirements before enabling phantom power. Equipment that is incompatible with 48 V can be damaged. Focusrite’s phantom power guidance
If one microphone needs 48 V and the other requires phantom power to stay off, use separate banks on the OctoPre Dynamic. Enable 48 V only for the bank that needs it.
On the ASP800, ASP880 or EVO SP8, use the per-channel controls to enable 48 V only for the microphone that needs it.
Set up eight ADAT channels at 96 kHz on a Scarlett 18i20 3rd Gen
-
Open Settings using the gear icon in Focusrite Control. Set Digital I/O Mode to Dual ADAT, then restart the interface. In Optical S/PDIF mode, Optical In 2 receives S/PDIF at 96 kHz. Scarlett 18i20 3rd Gen port assignments
-
Use two TOSLINK cables. Viewed from the rear of the OctoPre Dynamic, connect the right-hand ADAT output to Optical In 1 and the left-hand output to Optical In 2 on the interface.
At 96 kHz, the OctoPre’s right output sends channels 1–4 and its left output sends channels 5–8. In Dual ADAT mode, the 18i20 receives those channel groups on Optical In 1 and Optical In 2, respectively. OctoPre output map · 18i20 input map
-
Set the OctoPre’s SYNC to INTERNAL and its SAMPLE RATE to 96 kHz. Set the interface’s clock source to ADAT and match the interface and the recording session to 96 kHz. OctoPre clock setup · Sample rate and clocking
Choose a clock leader
Set the leader to its internal clock and set each follower to the clock source it receives. Match the sample rate across the preamp, interface and recording session. Focusrite’s clock and sample-rate guidance
| Setup | Connection and clock settings |
|---|---|
| Preamp leads over ADAT | If the interface can follow incoming ADAT, use the preamp’s internal clock and connect its ADAT output to the interface’s ADAT input. Set the interface to follow incoming ADAT clock. Focusrite clock setup |
| Interface leads over ADAT | Keep the preamp-to-interface audio connection. Add an optical cable from the interface’s ADAT output to the preamp’s ADAT input. Choose ADAT under SYNC on the OctoPre Dynamic or Digital under Clock Source on the EVO SP8. OctoPre clock setup · EVO SP8 clock setup |
| Interface leads over BNC word clock | Keep the ADAT audio connection. Run a BNC word-clock cable from the interface’s word-clock output to the preamp’s word-clock input. The OctoPre Dynamic, ASP800, ASP880 and EVO SP8 all provide that input. OctoPre · ASP800 · ASP880 · EVO SP8 |
For an interface-led setup with the ASP800 or ASP880, use a 75 Ω BNC coaxial cable for word clock and press SAMPLE RATE until LOCK flashes green. A solid green indicator confirms lock. Engage the rear termination switch if the preamp is the only or final device in the word-clock chain. ASP800 word clock · ASP880 word clock
For BNC sync on the EVO SP8, select Word Clock under Clock Source. With Word Clock or Digital selected, set Sample Rate to Auto unless the documented system configuration requires otherwise. EVO SP8 clock settings
The OctoPre Dynamic can also lead over BNC. Connect its WORD CLOCK OUT to the receiving device’s word-clock input and set that device to follow its external word-clock input. OctoPre clock setup
For published performance figures, see the Scarlett OctoPre Dynamic technical specifications. If your setup fails to lock or pass audio, see Focusrite’s ADAT troubleshooting checklist.
Evidence and limits
This guide is based on Focusrite’s Scarlett manuals and support articles and Audient’s ASP800, ASP880 and EVO SP8 documentation, checked November 29, 2026. The comparison covers connections, channel capacity and controls. No hands-on testing was performed for this guide.