The speaking tube · level helper

Mic level and ADAT channel helper

Type the figures from your own spec sheets and manuals. The helper does the arithmetic and shows the working. It knows nothing about any microphone, preamp or interface model, and it never suggests a gain, a pad or a level. Every result is an estimate.

Mic level after gain

From the microphone's spec sheet. A figure given in dBV re 1 V/Pa needs converting first.
94 dB SPL is 1 pascal, the level most spec sheets quote sensitivity at.
The gain you have set or plan to set, from the preamp's markings or manual.
Leave empty or type 0 when no pad is engaged.
From the interface manual: the maximum input level of the line input or converter that the preamp's output feeds.

Fill in the five figures and press "Work out the level". The result is an estimate.

ADAT channels over optical

Count the optical inputs on the interface that will carry ADAT.
Both ends must run at this rate and agree on one clock leader.

Fill in the number of ports, pick the rate and press "Count the channels". The count is an estimate to check against both manuals.

How the estimate is worked out

  1. Mic output (mV) = sensitivity (mV/Pa) × 10(SPL − 94) ÷ 20. The 94 is the sound level of 1 pascal: 20 × log10(1 Pa ÷ 20 µPa) = 93.98, rounded to 94 dB SPL as spec sheets do.
  2. In dBu = 20 × log10(V ÷ 0.7746 V). The 0.7746 V reference is √(0.001 W × 600 Ω), the voltage that puts 1 mW into 600 Ω.
  3. Level after gain and pad (dBu) = mic output (dBu) + gain (dB) − pad (dB).
  4. Margin (dB) = the converter maximum you typed (dBu) − level after gain and pad.
  5. ADAT channels = optical ports × channels per port: 8 at 44.1 or 48 kHz, 4 at 88.2 or 96 kHz (S/MUX) and 2 at 176.4 or 192 kHz (S/MUX4).

Assumptions

  • Levels are rms values of a steady tone. Real speech and music peak well above their average.
  • Sensitivity is the open-circuit figure the maker quotes at 1 kHz and 94 dB SPL. The preamp's input loads the microphone a little, which the helper ignores.
  • Gain and pad add and subtract exactly as marked. Real controls may not be calibrated to the decibel.
  • The converter maximum is the maximum input level your interface manual gives for the line input or converter that the preamp's output feeds. The preamp gain is counted once, in the level after gain.
  • Channel counts are the usual ADAT figures. Not every device supports every rate over ADAT, so check both manuals.

Reference values

  • 20 µPa is the reference sound pressure for dB SPL in air, the value set in the ISO 1683 standard on acoustical reference values. To confirm against the standard.
  • 0.7746 V is the dBu reference, worked out above from 1 mW into 600 Ω. To confirm against your interface manual's own level figures.
  • The channels per port are the usual ADAT figures, with S/MUX above 48 kHz. To confirm in the manuals of both devices.